<< Click to Display Table of Contents >> Logger Depth |
There are two ways to handle EQuIS Live data retrieved from varying depths:
1.Multiple Series: One may setup a new logger series (DT_LOGGER_SERIES) for each depth at which data are collected. Name the series to describe its purpose (e.g., Temp_2m for measuring temperature at a depth of 2 meters) and optionally populate DT_LOGGER_SERIES.DEPTH.
2.DT_LOGGER_DEPUM: Standing for "LOGGER DEPth datUM", this table contains logger data collected at a distinct time set on the logger itself, but over varying depths.
a.Set a time frame for the measurements using DT_LOGGER.START_DATE and .END_DATE.
b.Set the series to be a depth series: DT_LOGGER_SERIES.SERIES_TYPE = DEPUM.
c.Descriptions of fields in this table are as follows:
Column Name |
Data Type |
Description |
LOGGER_SERIES_ID |
int |
The unique identifier of the logger series associated with the datum. |
DATUM_DEPTH |
decimal |
The depth at which the datum was collected. |
DATUM_DEPTH_OFFSET |
decimal |
The depth offset of the datum. |
DATUM_VALUE |
real |
The value recorded. |
DATUM_QUALIFIER |
char (4) |
A user-defined qualifier for the record, if desired. |
Copyright © 2023 EarthSoft, Inc • Modified: 26 Apr 2022