<< Click to Display Table of Contents >> Navigation: EQuIS Library > Reports > EarthSoft Standard Reports > Flow > Flow Statistics |
Report Name: Flow Statistics (example)
File Name: EarthSoft.Reports.Library.178519.dll
Dependencies: This report does not have any dependencies.
Software: EQuIS Professional and EQuIS Enterprise
Source: EQuIS Professional install
Language: English
Output Type: Report Grid1
Description: The Flow Statistics Report presents the statistics of DT_FLOW that meet users’ selected parameters. When action level parameters are selected, the report examines the statistical values of instant_flow, average_flow or cumulative_flow with the selected action levels and flags a value if it breaks an action level value.
Installation Instructions: This report assembly is part of the EQuIS Professional installation. No additional installation steps are necessary.
Overview:
Statistical Calculation:
1.First, select a field of DT_FLOW to be calculated in the Statistics\Flow Type: parameter.
2.Second, select the Statistics\Aggregate By parameter as explained below.
a.When Statistics\Aggregate By is Year, the statistical values are calculated for each group of facility_id, sys_loc_code, flow_unit and the year of the measurement_start_date.
b.When Statistics\Aggregate By is Month, the statistical values are calculated for each group of facility_id, sys_loc_code, flow_unit and the year-month of the measurement_start_date.
c.When Statistics\Aggregate By is All, the statistical values are calculated for each group of facility_id, sys_loc_code, flow_unit and the (minimum – maximum) of the measurement_start_date.
Action level and violation:
Naming convention and the logic on linking action_level to flow measurement:
1.DT_ACTION_LEVEL_PARAMETER.PARAM_CODE must start with instant_, average_ or cumulative_ in order to link an action level to instant_flow, average_flow or cumulative_flow respectively.
Warning: The report will ignore action level information if a selected action level code with the DT_ACTION_LEVEL_PARAMETER.PARAM_CODE of no prefix instant_, average_ or cumulative_.
2.The final field name of an action level of DT_ACTION_LEVEL_PARAMETER in the report result is constructed with PARAM_CODE_ACTION_LEVEL_CODE.
3.The final field name of flagging an action level is constructed with param_code_action_level_code_flag.
4.If a value of the Flow Unit parameter is selected, the report will do a unit conversion for an action level from DT_ACTION_LEVEL_PARAMETER.UNIT to the flow unit.
5.Action level violation or flagging exceedances: when an instant_flow, average_flow or cumulative_flow exceeds the action_level value of its param_code, the value of the param_code_action_level_code_flag is populated with x.
Tables: DT_FLOW
Report Parameters |
||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Report Output |
||
---|---|---|
SYS_LOC_CODE EQUIPMENT_CODE PARAM_CODE INTERVAL_START_DATE or MEASUREMENT_DATE or MYYEAR TIME_INT REPORT_FLOW_VOLUME WARNING_LEVEL_MAX |
ACTION_LEVEL_MAX MAX_WARNING_LEVEL_HIT MAX_ACTION_LEVEL_HIT WARNING_LEVEL_MIN ACTION_LEVEL_MIN MIN_WARNING_LEVEL_HIT |
MIN_ACTION_LEVEL_HIT REPORT_FLOW_VOLUME_UNIT ACTION_LEVEL_REMARK AVERAGE_REPORT_FLOW_RATE or REPORT_FLOW_RATE REPORT_FLOW_RATE_UNIT |
Data Requirements: For general output, DT_FLOW must be populated. For action level output, DT_ACTION_LEVEL_PARAMETER.PARAM_CODE must start with instant_, average_ or cumulative_ in order to link an action level to instant_flow, average_flow or cumulative_flow respectively.
Report Requirements: N/A