<< Click to Display Table of Contents >> Navigation: DQM > DQM Checks > Required Detection Limit Check |
The DQM Check for Required Detection Limit compares the "reporting detection limit" of each result to a client specified "project required detection limit" for each analyte.
Check name is EarthSoft.DQM.RequiredDetectionLimit = Required Detection Limit.
This check uses three Global Parameters:
1.reportable_result – DT_RESULT.REPORTABLE_RESULT values to include in DQM datasets
2.result_type_code – DT_RESULT.RESULT_TYPE_CODE to include in DQM datasets
3.test_type_batch – AT_TEST_BATCH_ASSIGN.TEST_BATCH_TYPE to include in DQM dataset
Five parameters are specifically available for this Check. None of these parameters allow for input of analyte-specific or method-specific PARAM_VALUEs. However the check itself requires the population of REQUIRED_DETECT_LIMIT and REQUIRED_DETECT_LIMIT_UNIT columns of the RT_DQM_CONTROL_LIMITS table for each Analytic Method and/or CAS_RN.
1.detection_limit_column – To allow the user to specify which DT_RESULT column to use as the "reporting detection limit":
oREPORTING_DETECTION_LIMIT
oMETHOD_DETECTION_LIMIT or
oQUANTITATION_LIMIT
2.sample_type_code – Defaults to "N".
3.result_type_code – Defaults to "TRG".
4.non-adjusted_only – Defaults to "N". Selection of "Y" will exclude results with a dilution factor > 1 from this check.
5.non_detect_only – Defaults to "Y". Selection of "N" will include results with DETECT_FLAG =Y in this check.
Note: Default parameter values listed above refer to the value provided in the DQM Starter QAPP.xlsx. |
There is one rule and it is "EXCEEDS REQUIRED DETECTION LIMIT".
Qualify a result if:
•DT_RESULT.REPORTING_DETECTION_LIMIT (or .METHOD_DETECTION_LIMIT or .QUANTITATION_LIMIT, depending on which column is specified by the detection_limit_column parameter) > RT_DQM_CONTROL_LIMITS.REQUIRED_DETECT_LIMIT
To enable this check to run, "project required detection limits" will need to be entered in the REQUIRED_DETECT_LIMIT and REQUIRED_DETECT_LIMIT_UNIT columns of the RT_DQM_CONTROL_LIMITS table for each Analytic Method and/or CAS_RN in the analytic results of the database.
In the Errors tab of the DQM Event Review Form these errors may be listed:
•"One of the required rules for this check is not present in the RT_DQM_RULE table."
If you receive this error, the QAPP can be updated following the How to Update Existing QAPPs documentation page.
•"The value in the {0} column is null or not numeric at" DT_RESULT.REPORTING_DETECTION_LIMIT (or .METHOD_DETECTION_LIMIT or .QUANTITATION_LIMIT, depending on which column is specified by the detection_limit_column parameter).
•"The REQUIRED_DETECTION_LIMIT column in RT_DQM_CONTROL_LIMITS is NULL for SYS_SAMPLE_CODE = 'XXX'; ANALYTIC_METHOD = 'YYY'; CAS_RN = 'ZZZ'"
RT_DQM_CONTROL_LIMITS.REQUIRED_DETECT_LIMIT is null or not numeric for the record listed. The check will be skipped for this record.
•"The DILUTION_FACTOR column is NULL or not numeric at SYS_SAMPLE_CODE = 'XXX'; ANALYTIC_METHOD = 'YYY'; CAS_RN = 'ZZZ'"
DILUTION_FACTOR is null or non-numeric when non_adjust_only =Y for the record listed. The check will be skipped for this record.
Copyright © 2023 EarthSoft, Inc • Modified: 11 Oct 2022