<< Click to Display Table of Contents >> Navigation: DQM > DQM Checks > Blank Contamination Checks > Field Blank Contamination Check |
The DQM Check for Field Blank Contamination identifies detected concentrations of target analytes in field blanks. If a detected analyte in a field blank is also contained in an associated sample at a similar level as that in the blank, DQM will qualify the associated sample result.
The check name is EarthSoft.DQM.FieldBlankContamination.
This check uses four Global Parameters:
1.reportable_result – DT_RESULT.REPORTABLE_RESULT values to include in DQM datasets
2.result_type_code – DT_RESULT.RESULT_TYPE_CODE to include in DQM datasets
3.test_type_batch – AT_TEST_BATCH_ASSIGN.TEST_BATCH_TYPE to include in DQM dataset
4.nondetect_detection_limit – Identifies which detection limit column from DT_RESULT to populate DT_RESULT.RESULT_VALUE
This check uses the following seven check parameters (listed below). None of these parameters allow for input of method-specific PARAM_VALUEs in RT_DQM_CHECK_PARAM. However, the common_lab_multiplier allows for input of analyte-specific PARAM_VALUEs. Additionally, matrix-specific AND analyte- or method-specific multipliers can be used by populating RT_DQM_CONTROL_LIMITS.BLANK_MULTIPLIER. Using a multiplier from RT_DQM_CONTROL_LIMITS is discussed in more detail here.
1.AmbientBlankSampleType – the SAMPLE_TYPE_CODE used for ambient blanks – defaults to "AB".
2.EquipmentBlankSampleType – the SAMPLE_TYPE_CODE used for ambient blanks – defaults to "TB".
3.FieldBlankSampleType – the SAMPLE_TYPE_CODE used for field blanks - defaults to "FB".
4.Multiplier – used by DQM to determine if result can be qualified as non-detect - defaults to 1. Must be an integer.
5.Common_lab_multiplier – used by DQM to determine if a result identified as a common laboratory contaminant can be qualified as non-detect; depends on CAS_RN field being populated and defaults to 2. Must be an integer.
6.Flag_blank – if TRUE, the field blanks are also qualified – defaults to "TRUE".
7.Normal_sample_types – the SAMPLE_TYPE_CODEs used for standard association of field blanks – defaults to “N”.
Note: Default parameter values listed above refer to the value provided in the DQM Starter QAPP.xlsx. |
There are six rules:
1.BLANK CONTAMINATION < QL - Contamination detected in the Blank less than the Quantitation Limit
2.BLANK CONTAMINATION >= QL - Contamination detected in the Blank greater than or equal to the Quantitation Limit.
3.RESULT/DF < QL - Associated Result / Dilution Factor < Quantitation Limit.
4.RESULT/DF >= QL OR >= BLANK * MULTIPLIER - For Blank Conc < QL, Associated Result / Dilution Factor >= Quantitation Limit OR >= multiplier * concentration detected in the associated blank.
5.RESULT/DF >= QL & < BLANK * MULTIPLIER - For Blank Conc >= QL, Associated Result / Dilution Factor >= Quantitation Limit AND < multiplier * concentration detected in the associated blank.
6.RESULT/DF >= BLANK * MULTIPLIER - For Blank Conc >= QL, Associated Result / Dilution Factor >= multiplier * concentration detected in the associated blank.
There were 3 different blank rules available in 7.21.1 and earlier builds (BLANK CONTAMINATION, RESULT > BLANK * MULTIPLIER, RESULT < BLANK * MULTIPLIER). If those 3 rules exist in a DQM QAPP, along with the 6 rules listed above, then only the 6 above rules, available starting in version 7.21.2, will be used by DQM. In order for the 3 rules available in 7.21.1 and earlier to be used by DQM, then only those 3 rules should be included in the DQM QAPP.
DQM Associated results are found by:
1.Matching results (with detected concentrations only) using DT_FIELDQC_BATCH_PARTNER and Method, Fraction, CAS_RN. If matching samples are found, the process stops. DT_FIELDQC_BATCH_PARTNER is populated by selecting "Manual Associations For Field QC Samples" when creating a DQM Event or Collect/EDGE/EDP, see Field Batch Partner for additional information.
2.Matching results (with detected concentrations only) by Method, Fraction, CAS_RN and FIELD_SDG. If matching samples are found, the process stops.
3.If no matching results are found in Step 1, results (with detected concentrations only) are matched by Method, Fraction, CAS_RN and CHAIN_OF_CUSTODY (COC).
Manual Association of samples to Field blanks is discussed here.
Use of Reason Codes with the rules is discussed here.
For Field Blanks
•Review blanks if Flag_blank = TRUE
•Review results with DT_SAMPLE.SAMPLE_TYPE_CODE = AmbientBlankSampleType, EquipmentBlankSampleType, and FieldBlankSampleType
•Qualify a result in a field blank if reportable_result = Y and detect_flag=Yes
1.If BLANK CONTAMINATION < QL - the apply_remark is “Contamination detected in the Blank less than the Quantitation Limit.”
An example dqm_remark for this exception is: “[0.5 < 1] Blank result < quantitation limit in this blank.”
2.BLANK CONTAMINATION >= QL - the apply_remark is “Contamination detected in the Blank greater than or equal to the Quantitation Limit.”
An example dqm_remark for this exception is: “[8 >= 1] Blank result >= quantitation limit in this blank.”
For Associated Samples
•Review results with DT_SAMPLE.SAMPLE_TYPE_CODE = Normal_sample_types
•Qualify a result in an associated sample if reportable_result = Y and detect_flag=Yes according to the following:
1.RESULT/DF < QL - the apply_remark is “Associated Result from: Associated Result / Dilution Factor < Quantitation Limit.”
An example dqm_remark for this exception is: “[0.3 / 1 < 1] Sample result / dilution factor < quantitation limit in this associated blank: (sys_sample_code:AQ_SAMPLE1_RC_TB, analytic_method:SW6010, cas_rn:7440-28-0).”
2.RESULT/DF >= QL OR >= BLANK * MULTIPLIER – the apply_remark is “Associated Result from: For Blank Conc < QL, Associated Result / Dilution Factor >= Quantitation Limit OR >= multiplier * concentration detected in the associated blank.”
An example dqm_remark for this exception is: “[5 / 1 >= 1 * 0.5] Sample result / dilution factor >= multiplier * concentration detected in this associated blank: (sys_sample_code:AQ_SAMPLE1_RC_TB, analytic_method:SW6010, cas_rn:7440-28-0)”
3.RESULT/DF >= QL & < BLANK * MULTIPLIER – the apply_remark is “Associated Result from: For Blank Conc >= QL, Associated Result / Dilution Factor >= Quantitation Limit AND < multiplier * concentration detected in the associated blank.
An example dqm_remark for this exception is: “[10 / 1 >= 1] AND [10 / 1 < 2 * 8] Sample result / dilution factor >= quantitation limit AND < multiplier * concentration detected in this associated blank:(sys_sample_code:AQ_SAMPLE1_RC_TB, analytic_method:SW6010, cas_rn:7782-49-2).”
4.RESULT/DF >= BLANK * MULTIPLIER – the apply_remark is “Associated Result from: For Blank Conc >= QL, Associated Result / Dilution Factor >= multiplier * concentration detected in the associated blank.
An example dqm_remark for this exception is: “[10 / 1 >= 1 * 8] Sample result / dilution factor >= multiplier * concentration detected in this associated blank: (sys_sample_code:AQ_SAMPLE1_RC_TB, analytic_method:SW6010, cas_rn:7782-49-2).”
1.Blank unit error
This check includes an internal unit conversion function, which allows blanks with units for liquids to be compared to results for soil samples. This internal function
includes:
▪ug/L to mg/kg
▪ug/L to ug/kg
▪mg/L to mg/kg
▪mg/L to ug/kg
▪Any combination of units found in RT_UNIT_CONVERSION_FACTOR will also be used.
The following error message occurs if the units differ and none of the above conversion factors apply:
“Associated result has units ({0}) that do not convert to units of blank result ({1}).” |
For this check to work, a record must be added to RT_UNIT_CONVERSION_FACTOR for that combination.
2.Result Numeric is null
If the RESULT_NUMERIC column is null in the blank or the associated sample for a result, the following error message will be created:
“The RESULT_NUMERIC column is NULL in blank or associated result.”